Engineering Consultant for Design, Engineering and Consultancy Services for Extra High Voltage Substations, Transmission Lines, Electrical Balance of Plant (EBOP) of Thermal Power Plants, Large Electrical Systems (HV/MV) of Steel plants, Coal & Iron Handling Plants & Misc. Industries, Electrical System studies using ETAP 2020.
Are you looking for Extra High Voltage Engineering Consultancy Services in Kolkata ? We are providing the same for Substations and Transmission Lines upto 765kV Voltage level.
Engineering Consultant for Design, Engineering and Consultancy Services for Extra High Voltage Substations, Transmission Lines, Electrical Balance of Plant (EBOP) of Thermal Power Plants, Large Electrical Systems (HV/MV) of Steel plants, Coal & Iron Handling Plants & Misc. Industries, Electrical System studies using ETAP 2020.
Are you looking for Extra High Voltage Engineering Consultancy Services in Kolkata ? We are providing the same for Substations and Transmission Lines upto 765kV Voltage level.
Scope of work :
The scope included site visit, data collection, discussion with Client and submission of the following detail engineering drawings :
SL. NO. | DESCRIPTION |
A. | DRAWINGS : |
1 | SLD |
1.1 | 400kV Switchyard - Protection & metering SLD (Power Plant End) |
1.2 | 33kV Switchyard - Protection & metering SLD |
1.3 | SLD - DCDB |
1.4 | SLD - ACDB |
1.5 | SLD - MLDB |
1.6 | SLD - 415V PCC |
1.7 | SLD - Marshalling Kiosk |
2 | ELECTRICAL LAYOUT & ELEVATION, EKD |
2.1 | 400kV Switchyard Layout - Plan (Power Plant End) |
2.2 | 400kV Switchyard Layout - Section (Power Plant End) |
2.3 | 400kV Switchyard - Erection key diagram - plan (Power Plant End) |
2.4 | 400kV Switchyard - Erection key diagram - section (Power Plant End) |
2.5 | 33kV Switchyard Layout - Plan & section |
2.6 | 33kV Switchyard - Erection key diagram - plan & section |
2.7 | Electrical equipment layout - control building |
2.10 | Electrical equipment layout - air conditioned bay marshalling kiosks |
3 | CABLE ROUTING, TRAY & TRENCH LAYOUT AND DETAILS |
3.1 | 400kV Switchyard - Cable trench layout and sections (Power Plant End) |
3.2 | 33kV Switchyard - Cable trench layout and sections |
3.3 | Cable tray, trench Layout & Sections - Control Building |
3.4 | Cable tray, trench Layout & Sections - Air conditioned bay marshalling kiosks |
4 | EARTHING LAYOUT & DETAILS |
4.1 | 400/33kV Switchyard - Earthing layout (Power Plant End) |
4.2 | Earthing layout - Control building |
4.3 | Earthing layout - Air conditioned bay marshalling kiosk |
4.4 | Earthing Notes & Details |
5 | LIGHTNING PROTECTION LAYOUT & DETAILS |
5.1 | 400kV Switchyard DSLP layout (Power plant end) |
5.2 | 33kV Switchyard DSLP layout |
5.3 | Lightning protection layout - Control Building |
5.4 | Lightning Protection Notes & Details |
6 | ILLUMINATION LAYOUT |
6.1 | 400kV Switchyard - Illumination layout, SLD and BOM (Power plant end) |
6.2 | 33kV Switchyard - Illumination layout, SLD and BOM |
6.3 | Illumination layout, SLD and BOM - Control building |
6.4 | Lighting Notes & Details |
7 | CONTROL SCHEMATICS |
7.1 | 400KV Intelocking Logic Diagram |
7.2 | 33KV Intelocking Logic Diagram |
7.3 | Control cabling block diagrams - 400kV |
7.4 | Control cabling block diagrams - 33kV |
8 | CABLE SCHEDULE & INTERCONNECTION DIAGRAMS |
8.1 | 400kV switchyard - Power and control Cable schedule and Interconnection Diagrams (Power plant end) |
8.2 | 33kV switchyard - Power and control Cable schedule and Interconnection Diagram |
8.3 | 415V PCC - Power and Control Cable Schedule and Interconnection Diagrams |
8.4 | ACDB, DCDB - Power Cable Schedule and Interconnection Diagram |
B | DESIGN CALCULATIONS |
1 | Strung bus short circuit force calculation (Power plant end) |
2 | Sag-tension calculation of strung bus (Power plant end) |
3 | Rigid bus short circuit force and span calculation (Power plant end) |
4 | 400/33kV Switchyard - Earthing calculation (Power Plant End) |
5 | 400kV Switchyard DSLP calculation (Power plant end) |
6 | 33kV Switchyard DSLP calculation |
7 | Calculation for selection of 400kV CTs and PTs |
8 | Calculation for selection of 33kV CTs and PTs |
9 | Fault Level Calculation |
10 | DC Battery Sizing Calculation |
11 | Lighting calculation - Control Building |
12 | Lighting calculation - 400kV switchyard (Power plant end) |
13 | Lighting calculation - 33kV switchyard |
C | BILL OF MATERIALS |
1 | Clamps and connectors |
2 | HT and LT cables, cable termination kits, cabling accessories |
Rajasthan - 220 KV Switchyard Structure & Foundation Design - 400 MW S..
Himachal Pradesh - 220/132/22kV Switchyard including 80/100MVA Power T..
Himachal Pradesh - 66/11kV Switchyard for Design, Build, Operate contr..
West Bengal - Complete Design, Engineering and Site Supervision servic..